1. Purpose and Engineering Decision

A dryer catalogue capacity is valid only at the rating conditions stated by its manufacturer. Actual compressed-air inlet temperature, operating pressure, ambient temperature, cooling-water condition, required pressure dew point and other model-specific variables can change the usable capacity materially.

The engineering decision is simple: can the selected dryer process the required design flow at the actual project conditions while remaining inside the supplier's operating envelope and preserving an explicit capacity margin?

Mode

Primary output

Single-model check

Corrected usable capacity and margin at actual conditions

Required nominal size

Minimum catalogue rating needed after supplier correction method

Two-model comparison

Like-for-like corrected capacities with factor provenance kept separate

Sensitivity

Which project condition most strongly reduces model capacity

Documented model, source table, revision, factors, operating envelope and result

2. Non-Negotiable Rule - The Supplier Method Governs

There is no safe universal correction-factor table for all compressed-air dryers. Even when two suppliers use similar labels such as inlet-temperature factor, pressure factor or ambient factor, the numerical factors and the way they are combined can differ.

If the model's correction method is missing, unclear or outside its published range, the worksheet returns INCOMPLETE / SUPPLIER CONFIRMATION REQUIRED rather than creating an engineering factor.

Prohibited shortcut

Use a generic internet factor table

Rejected unless the exact model documentation explicitly adopts it

Reuse a factor from another brand

Rejected

Reuse a factor from another dryer technology

Rejected

Interpolate outside the published correction table

Blocked unless the manufacturer explicitly permits the interpolation/extrapolation method

Assume factors multiply

Not allowed until the supplier equation is confirmed

Assume factors divide

Not allowed until the supplier equation is confirmed

3. Model-Referenced Dryer Selection Sheet - Required Asset

Field

Required entry

Evidence / control

Manufacturer / supplier

Exact name

Quotation / datasheet / manual

Dryer model

Exact model code

No family substitution without proof

Dryer technology

Refrigerated / adsorption / membrane / other

Model documentation

Rated capacity

Value + unit + flow basis

Published rating

Rated inlet pressure

Value + gauge/absolute basis

Published rating condition

Rated inlet temperature

Value

Published rating condition

Rated ambient / cooling condition

Value

Air-cooled / water-cooled basis

Rated PDP / outlet condition

Value

Published performance point

Required project flow

Design flow + margin policy

Actual project conditions

Pressure / inlet temp / ambient / water / PDP

Design data

Correction source

Document name, revision, page/table

Mandatory

Correction equation

Exact supplier method

Mandatory

Corrected capacity

Calculated

Traceable result

Selection margin

Corrected capacity - required flow

Pass / fail

Operating envelope

Inside / outside

Independent gate

4. Correction-Method Engine

The worksheet must store the supplier's calculation convention rather than hard-code one universal equation. Three common calculation patterns can be supported as selectable methods, but only after the model documentation identifies which pattern applies.

Supplier method

Engine expression

Use only when

Capacity multiplier

Q_corrected = Q_rated x F1 x F2 x ... x Fn

Supplier defines factors as multipliers on rated capacity

Required-rating divisor

Q_required_rated = Q_project / (F1 x F2 x ... x Fn)

Supplier defines factors to derate rated capacity

Mixed / formula-specific

Use supplier equation exactly

Supplier uses a non-product formula, lookup or staged correction

The UI must display the selected convention beside the result. A reviewer should be able to reconstruct the result without guessing whether a factor was multiplied or divided.

6. Rated Capacity Must Include Its Flow Basis

A dryer rating such as 30 m3/min is incomplete if the flow reference condition is unknown.

The worksheet must not correct dryer capacity and flow-reference basis simultaneously using undocumented assumptions. Flow normalization and dryer derating are separate calculation steps.

7. Operating Envelope Gate

Passing the corrected-capacity calculation is not enough. The actual conditions must also remain within the model's published minimum/maximum operating envelope.

Envelope item

Gate

Minimum / maximum inlet pressure

Actual must lie inside published range

Maximum inlet air temperature

Actual must not exceed published limit

Ambient temperature range

Actual must remain inside range for air-cooled units

Cooling-water temperature / flow

Must satisfy model requirement for water-cooled units

Maximum flow / overload condition

Must remain within supplier allowance

Specified pressure dew point

Must be achievable at stated conditions

8. Refrigerated Dryer Worksheet Boundary

For a refrigerated dryer, the published correction method commonly responds to inlet air temperature, operating pressure, ambient temperature or cooling-water condition.

Pressure dew point performance and maximum inlet-temperature limits remain separate checks. A corrected flow capacity does not prove the required PDP if the actual operating condition lies outside the model's performance envelope.

9. Adsorption Dryer Worksheet Boundary

For adsorption dryers, corrected capacity can interact with regeneration method, inlet temperature, operating pressure, required PDP and purge or blower duty.

10. Reference Test Case A - Multiplier Convention (Synthetic Validation Dataset)

The following numbers are a deliberately synthetic software-validation dataset. They are not a manufacturer rating and must never be used for equipment selection. Assume Example Model A is rated at 30.0 m3/min and its fictional validation sheet defines four multiplicative factors: pressure 1.06, inlet temperature 0.88, ambient 0.92 and PDP 0.95.

Q_corrected = 30.0 x 1.06 x 0.88 x 0.92 x 0.95

Item

Result

Combined synthetic factor

0.8153

Corrected capacity

24.46 m3/min

Project required flow

22.00 m3/min

Capacity margin

2.46 m3/min (11.2%)

Software selection result

PASS, provided the independent operating-envelope gate also passes

11. Reference Test Case B - Required-Rating Divisor Convention (Synthetic Validation Dataset)

Example Model Family B uses a fictional divisor convention for software validation. Project flow is 25.0 m3/min and the synthetic factor product is 0.78.

Required catalogue rating = 25.0 / 0.78 = 32.05 m3/min

A model rated below this synthetic required rating fails the validation case. The result demonstrates why the factor convention must be stored with the model source.

12. Reference Test Case C - Never Mix Supplier Factors

Supplier X and Supplier Y both quote dryers at 30 m3/min catalogue capacity. Supplier X's own documented method gives a corrected capacity of 24.5 m3/min at the project conditions; Supplier Y's own documented method gives 26.2 m3/min.

Candidate

Catalogue rating

Correction source

Corrected capacity

Decision

Supplier X - Model X

30 m3/min

X model sheet only

24.5 m3/min

Compare with project duty

Supplier Y - Model Y

30 m3/min

Y model sheet only

26.2 m3/min

Compare with project duty

13. Reference Test Case D - Capacity Math Passes, Envelope Fails

A hypothetical validation model calculates 28 m3/min corrected capacity against a 24 m3/min project requirement, but the actual inlet temperature is 52 C while the fictional validation envelope ends at 45 C.

Check

Result

Corrected-capacity check

PASS

Published operating-envelope check

FAIL - inlet temperature outside stated range

Final worksheet status

FAIL / SUPPLIER CONFIRMATION REQUIRED

The independent envelope gate prevents a numerically adequate but technically invalid selection from being accepted.

14. Required Capacity Margin

Capacity Margin = Q_corrected - Q_required

Margin (%) = (Q_corrected / Q_required - 1) x 100

The worksheet should not impose a universal spare-capacity percentage. The project margin is entered explicitly and should reflect growth policy, measurement uncertainty, seasonal operating conditions and the site's redundancy philosophy.

15. Dirty / Aged System Allowance

Dryer capacity correction and pressure-drop allowance are different issues.

16. Sensitivity Review

This is a decision aid, not a replacement for supplier data.

Sensitivity step

Method

Baseline

Use all actual project factors

One-factor-at-reference

Return one condition to the supplier reference value while keeping others fixed

Capacity recovery

Q_with_factor_reset - Q_baseline

Rank

Largest recoverable capacity first

17. Input Model

Input group

Field

Validation / note

Model

Manufacturer / supplier / model code

Mandatory

Rating

Rated capacity + flow basis

Mandatory

Rating

Rated pressure / inlet temperature / ambient / PDP

Mandatory where supplier states them

Project

Required design flow

> 0

Project

Actual pressure / inlet temp / ambient / water / PDP

As applicable

Factors

Exact factor values

Must carry source location

Method

Multiply / divide / supplier formula

Must match source

Margin

Project capacity margin

Explicit

Envelope

Published min/max conditions

Mandatory for final PASS

Evidence

Document / revision / page / table / quotation

Mandatory for factors

18. Validation and Guardrails

Condition

Required behaviour

Model code missing

Block final selection

Rated condition missing

Mark calculation incomplete

Factor has no source reference

Do not accept as verified

Factor outside published table

Block unless supplier method authorizes interpolation/extrapolation

Factor borrowed from another model/brand

Block

Supplier convention unknown

Block calculation

Project flow basis differs from rating basis

Operating condition outside model envelope

FAIL / supplier confirmation required

Corrected capacity <= 0

Block result

Required margin not met

FAIL / next model size or alternate configuration

19. Output Specification

Output

Display rule

Model identification

Always visible beside result

Supplier rating conditions

Complete source basis

Actual project conditions

Side-by-side with rated conditions

Factor table

Value + source location + method

Combined correction

Only according to supplier method

Corrected capacity

Selected flow unit

Required flow + margin

Explicit

Operating-envelope status

Independent PASS / FAIL

Final selection status

PASS / FAIL / INCOMPLETE / SUPPLIER CONFIRMATION

Warnings

No generic factors; basis mismatch; unsupported interpolation; envelope violation

Calculators and worked examples

These tools give indicative figures for screening, comparison and for preparing an enquiry. They run in your browser and send nothing. Prices, tariffs and efficiencies shown are example values: replace them with your own. Results are not a performance guarantee or a design certificate; final selection is confirmed by an engineer against the machine data sheet and the site.

Moisture load at the dryer inlet

Estimate how much water a compressor puts into the air system each hour, and how much a dryer or aftercooler must remove.

The worked example below shows the method with fixed numbers. Turn on JavaScript to change the inputs.

Worked example

Inputs
  • Compressor flow (m³/min free air): 12
  • Intake air temperature (°C): 35
  • Intake relative humidity (%): 70
  • Delivery pressure (bar g): 7
  • Air temperature at dryer inlet (°C): 38
Result
  • Water entering with intake air: 19.9 kg/h
  • Water still held at dryer inlet: 4.5 kg/h
  • Condensate removed before the dryer: 15.4 kg/h (about 370 L per day)

Method. Water in = air × relative humidity × saturation vapour density (Magnus formula). Water the air can hold after compression = saturation at the dryer inlet temperature and pressure. Condensate = the difference. Dry-air basis; indicative.

What to take from it. This water must be removed somewhere: aftercooler separator, drains, dryer. A failed drain sends it into the pipework.