Reading CompressorPerformance Data Sheets

Read the declared duty, reference conditions and package boundary before comparing capacity, efficiency or a supplier promise.

1. Engineering answer: read the operating point, not the largest number

A compressor performance data sheet describes the output and input of an identified compressor configuration under stated conditions. Read the model and revision first, then connect delivered airflow, operating pressure, electrical input, control state, reference conditions and the notes that qualify them. A large airflow figure, a low specific-power value or an impressive motor rating is not a complete selection basis on its own.

A useful reading produces three outputs: a faithful record of what the supplier actually states; a clearly labelled set of calculations derived from those statements; and a short list of unresolved questions that affect suitability. None should replace the original document. The reader should be able to explain why a value belongs to the proposed machine, what condition it represents, and whether it can answer the plant's actual requirement.

The central rule is simple: compare a complete operating point on a compatible boundary. Where that cannot be established, retain the missing information rather than manufacture an apparently precise comparison.

2. The distinct purpose of this page

This resource owns performance-sheet interpretation and an annotated reading example. It is not another full procurement manual, an equipment-sizing certificate or a repeat of the units dictionary. The fixed sequence and page identity remain unchanged.

Use the reading workflow when receiving a quotation, checking a proposed replacement, comparing an electric compressor with an existing plant duty, reviewing a rental substitution or investigating a discrepancy between a brochure and a performance declaration. The same reading discipline can support other compressor technologies, but their reporting methods and operating envelopes must remain technology-specific.

The annotated sheet and four numerical cases below are explicitly fictional teaching examples. They are not manufacturer declarations, measured customer results or offers from Reddy Compressors. This allows the examples to be useful without disguising invented numbers as commercial evidence.

3. Establish document identity before extracting performance

Record the manufacturer, complete model suffix, drive configuration, cooling arrangement, electrical supply, document date and revision. A family name may cover several pressure variants, motor packages, frequencies, integrated treatment options or control configurations. A sheet for one variant cannot silently stand in for another because the enclosure or nominal motor size looks similar. Preserve the quoted model and the sheet model as separate fields until they match.

Check where the document came from. An identifiable manufacturer publication, a signed project-specific clarification, an undated distributor screenshot and a graph copied into a presentation carry different provenance. They can all be retained, but the reading record should say which one supports each material number. A filename containing “latest” is not proof that its internal revision is current or that it applies to the offered equipment.

Keep the original file, including footnotes and pages that appear commercially uninteresting. The voltage and frequency may sit in the model line; the flow definition may be below the main table; the power boundary may be in a separate note. Cropping the sheet to its largest numbers can remove the information needed to interpret those numbers.

Where two documents disagree, record the disagreement and request a controlled clarification. Do not resolve it by selecting whichever value creates the better apparent capacity or efficiency. A later revision may supersede an earlier one, but that relationship needs evidence and should not erase the earlier bid or comparison record.

4. Annotated example: fourteen fields that must travel together

The following teaching sheet is a deliberately compact, original example. Each annotation explains what a reader should preserve or question. It is not a reproduction of a manufacturer's form and must remain visibly labelled “fictional instructional example” in Word, HTML and any later website implementation.

The example is intentionally incomplete in a few important areas. This is not an invitation to guess. The unresolved site conditions, higher-pressure operating point and acceptance provisions demonstrate why a sheet can support a rated-point calculation while remaining insufficient for final selection.

Annotation

Teaching-sheet entry

Reading instruction

A1 — Identity

TEACHING FS-75-A; issue 1.0

Fictional fixed-speed, air-cooled package. Not an actual model.

A2 — Electrical variant

400 V; 3 phase; 50 Hz

Match the offered configuration and project supply; do not substitute another frequency.

A3 — Motor descriptor

75 kW nominal motor output

A motor descriptor, not the package electrical-input figure.

A4 — Rated delivery

14.4 m³/min

Delivered air at A5, expressed on the declared A6 reference basis.

A5 — Rated operating pressure

7.5 bar gauge

The flow and package power in this example belong to this operating point.

A6 — Flow reference

Dry air; 1.000 bar absolute; 20°C

A fictional declared reporting basis, not a universal definition of FAD.

A7 — Higher pressure capability

8.5 bar gauge; other-point power not supplied

Not permission to attach A4 and A8 unchanged to the higher setting.

A8 — Loaded package input

86.4 kW electrical

Includes main drive, package fan and internal controls in the teaching boundary.

A9 — Zero-delivery running input

24.0 kW electrical

Defined running-unloaded state; not a universal value for every idle condition.

A10 — Specific power

6.00 kW per m³/min

Check from A8/A4; preserve the rated pressure and boundary.

A11 — Treatment scope

External dryer and plant exhaust fan excluded

Add only documented external loads for a separate wider-system calculation.

A12 — Thermal/site applicability

Project confirmation outstanding

The rated point alone does not establish hot-weather or altitude performance.

A13 — Tolerances and acceptance

Not supplied in this teaching sheet

Remain unresolved; do not invent a standard percentage.

A14 — Verification status

Fictional instructional example

No verification seal, certification or supplier endorsement is claimed.

Read A4, A5, A6 and A8 as one linked operating record. A4 cannot be lifted into another pressure case, A6 cannot be replaced with an assumed standard condition, and A8 must not be divided by motor efficiency a second time. A11 defines a boundary change, not an error in A8.

An annotated reading should leave the source value intact. Store the original wording beside the interpretation so another person can challenge an incorrect reading. If the supplier later supplies a missing site rating, add a new linked operating-point record rather than overwriting the original rated case.

5. Separate a standard format from a verified performance claim

CAGI provides standardised data-sheet formats and describes a voluntary performance-verification programme for eligible equipment. The programme uses independent testing of selected equipment to assess participating manufacturers' published ratings. Standardised presentation and applicable verification are useful evidence, but they are different questions. Check the actual programme scope and the relevant supplier/model documentation rather than treating a familiar form as proof that every number or every delivered serial number was individually witnessed. [R1]

For the reading record, distinguish “manufacturer-published,” “verification status checked,” “project-specific supplier confirmation” and “site-tested.” These are proposed evidence labels, not claims of certification. A document can be manufacturer-published while a project-specific site condition remains unconfirmed. Conversely, a useful witnessed site observation may not constitute a complete formal acceptance test. [S2, S3; proposed record design]

Do not infer dealership, service authorisation, current inventory or suitability from a resource-directory entry. The supplied bookmark collection is a route to technical material, not evidence of a commercial relationship. Preserve that separation when the public page names a reference organisation or when a customer submits a supplier sheet for review.

6. Read rated pressure, maximum pressure and pressure limits separately

The pressure paired with capacity is part of the rating, not a decorative condition. A sheet may show a full-load operating pressure, a maximum full-flow pressure, a control setting and a pressure-containing limit. These labels answer different questions. Record the exact term used and the location to which it applies. A compressor's discharge condition is not the same as the required dynamic pressure at a machine after treatment and distribution.

A manufacturer-published fixed-speed example consulted for this page explicitly distinguishes the pressure used for the flow and input-power measurements from a higher maximum full-flow pressure, and warns that additional power may be needed. Its flow footnote also identifies the package discharge measurement point and an inlet-condition volume basis.

Do not take the maximum pressure and the highest flow from different rows or different documents and present them as a simultaneous duty. Ask for the offered configuration's supported flow and power at the required operating pressure. If a higher setting changes speed, unloading behaviour, cooling or electrical demand, the new operating point needs its own evidence.

Gauge and absolute pressure must remain identifiable. Unit conversion can change bar to kPa or psi on the same reference basis, but it cannot turn gauge into absolute pressure without the relevant atmospheric-pressure basis. Nor can a gas-volume equation predict a compressor's new mechanical performance when its discharge setpoint changes.

7. Find out what the airflow figure actually measures

Identify whether the figure represents delivered airflow, geometric displacement, inlet volume, actual line volume, reference volume or a meter-configured reporting value. The label CFM, acfm, scfm, Nm³/h or m³/min is not sufficient on its own. Keep the supplier's definition and the applicable conditions beside the number.

A compressed-air package can discharge gas at elevated pressure while reporting its delivered quantity as a volume referred to inlet or other specified conditions. The physical measurement location and the reference state used to express the result are therefore separate fields. An abbreviation containing “actual” must be read with the supplier's footnote; it should not automatically be assigned to the pressurised pipe condition.

Also identify which accessories lie before and after the declared terminal point. A dryer purge, drain loss, branch export or receiver charging event can make downstream useful delivery differ from compressor output. Do not deduct these terms twice if the supplier's net-delivery figure already includes them. Keep the flow diagram and accounting boundary with the reading record.

When comparing demand with supply, first reconcile the reporting basis and then reconcile the physical boundary. Changing m³/h into m³/min fixes a time-unit difference, not a wet-versus-dry definition or a missing treatment allowance. A plausible conversion factor can produce a numerically tidy but physically wrong capacity comparison.

8. Read the reference conditions without inventing site corrections

Separate the conditions used to report flow from the conditions under which the machine can operate. The former explain the numerical volume basis. The latter include the installation's intake, ambient and cooling conditions and the supplier's applicable limits. Neither is automatically an allowance for the other. A normalised flow label does not establish performance at every site temperature or elevation.

Record reference pressure, absolute temperature, humidity or dry-air convention, gas identity and any compressibility treatment when those are part of the method. If the sheet refers to a separate test method, retain that reference and request the needed definition rather than assuming every document uses the same “standard” or “normal” conditions. Where a required basis is missing, identify the affected comparison explicitly.

For the same dry-gas mass flow, an illustrative state relation is Q₂ = Q₁ × (p₁/p₂) × (T₂/T₁) × (Z₂/Z₁). This expression changes the reported gas volume under declared assumptions. It is not a machine-performance correction and does not establish capacity at a different discharge duty. [S1; explanatory extension]

Use supplier-backed information for site performance and accessory selection. Preserve original and corrected values, the method and its applicability. Avoid a universal altitude, temperature or humidity percentage. The right outcome of reading a sheet may be a request for a project-rated selection, not a home-made correction to a catalogue number.

9. Separate motor rating, motor input and total package input

A nominal motor rating describes the motor on its declared basis; it is not automatically the electrical consumption of the complete compressor package. A performance sheet may separately show main-motor efficiency, fan-motor details, package input at rated delivery and package input at zero flow. Retain these fields individually. Selecting the smallest visible kW value as the “compressor consumption” can materially understate the comparison.

CAGI's glossary describes total package input as including the compressor's electrical drive and associated package loads such as fans and controls. The exact declared boundary still governs an individual sheet. A separate plant cooling-water pump or external dryer should not be assumed included merely because it is needed to operate the installation. [R2]

Where total electrical package input is already stated, do not divide that number by the main-motor efficiency again. That would count a conversion already represented in the electrical input. Conversely, a shaft-power estimate may require an appropriate efficiency treatment before it represents electrical input; nominal motor efficiency is not proof of actual efficiency at every part-load point. [S2, S3; arithmetic interpretation]

Power label

What to retain

What not to assume

Nominal drive-motor rating

Value, unit and rating meaning

Actual package input equals the nameplate value.

Motor efficiency

Applicable rating condition and source

The same efficiency applies to every speed and load.

Rated package electrical input

Flow, pressure, state and included auxiliaries

External treatment or plant services are included without confirmation.

Zero-flow package input

Running, unloaded, stopped or declared test state

Zero useful air always means zero electricity.

System electrical input

A separately defined sum of compatible loads

An extra motor should be added when it is already inside package input.

10. Recalculate specific power before interpreting efficiency

Specific power is a power-to-flow ratio on a defined basis. With electrical input P in kW and delivered flow Q in m³/min, SP = P/Q, in kW per m³/min. A smaller ratio uses less electrical power per unit of reported flow at the compared operating point, but only a compatible pressure, gas reference and equipment boundary make the comparison meaningful. Preserve both numerator and denominator instead of retaining only the ratio.

Where flow is in ft³/min, SP₁₀₀ = 100P/Q_cfm gives kW per 100 cfm. Pure unit conversion uses 1 ft³ = 0.028316846592 m³, with no change of gas reference. A denominator of 100 cfm is not interchangeable with a denominator of one m³/min. The conversion is SP_SI = SP₁₀₀/2.8316846592.

For a steady compatible boundary, specific electrical energy e = P/(60Q), in kWh/m³. Over varying operation, use integrated electrical energy divided by integrated delivered reference volume. Do not average individual specific-power ratios without considering their flow and duration weights. Keep package-specific energy separate from useful delivered-air energy when losses or external loads change the boundary.

Expression

Output unit

Required interpretation

P / Q, with Q in m³/min

kW per m³/min

Single stated duty point or compatible ratio of time-weighted means.

100P / Q_cfm

kW per 100 cfm

Flow definition and pressure must accompany the cfm value.

P / (60Q)

kWh/m³

Steady electrical-input and reference-volume boundary.

Σ(Pᵢhᵢ) / Σ(60Qᵢhᵢ)

kWh/m³

Same intervals, valid operating states and matched boundaries.

Small differences between a recalculated ratio and a printed ratio may arise from rounded inputs. Record the discrepancy and the displayed precision before describing an error. A larger difference can indicate a mismatched row, a denominator of 100, a missing auxiliary or a different rating boundary. Arithmetic is a screening check, not independent proof that the underlying measurements are correct.

11. Interpret isentropic efficiency without confusing it with motor efficiency

CAGI explains isentropic efficiency as a comparison with an idealised compression process and uses it to improve comparisons where similar compressors have slightly different operating pressures. It is distinct from motor efficiency and is derived from pressure, flow and power on the governing method's basis. Preserve the reported metric and method rather than trying to reconstruct an official declaration from incomplete brochure fields. [R2, R3]

For this reading workflow, do not multiply a reported isentropic efficiency by motor efficiency to create an invented “overall useful efficiency.” Do not assume that a higher percentage establishes the lowest annual cost at the plant's demand profile. A single headline may represent a declared point or a method-defined aggregate; the sheet and supporting method should identify which. [Original interpretation applying S2]

Use the metric for its stated comparison purpose alongside capacity, required pressure, part-load behaviour and the installation boundary. It does not remove a capacity shortfall, prove process-air purity or establish the condition of an existing used machine. Record missing method information as a clarification, not as a zero or a favourable default.

12. Read fixed-speed performance with its control states

A fixed-speed rated point describes loaded operation, not every hour for which the motor is enabled. When the package unloads, modulates, stops or cycles, both output and electrical input can change. The supplied procurement material specifically requests unloaded power and control behaviour where they matter. A reader therefore needs the intended operating pattern as well as the rated row.

A two-state teaching model is P_average = fP_loaded + (1−f)P_unloaded, where f is the share of the defined running period spent loaded. Under the additional assumption of full rated delivery while loaded and zero delivery while unloaded, Q_average = fQ_loaded. This model excludes transition effects, variable pressure, shutdowns and other states. It is a declared approximation, not a generic compressor control curve.

Do not infer that a package drawing sixty percent of rated airflow consumes sixty percent of rated power. Use actual or supported control-state information. Record whether hours represent calendar time, enabled time, motor-running time or loaded time. Applying a running-hour model to all calendar hours can overstate or understate energy depending on the omitted states.

A zero-flow entry must retain its test and reporting conditions. It cannot settle every real-world standby load, auxiliary cycle or restart event.

13. Read variable-speed tables as operating points, not a straight line to zero

A variable-speed sheet should be read row by row. Keep each stated flow paired with its electrical input, specific power and operating pressure. The lowest reported flow and the highest reported flow define the published information in that configuration; neither alone proves the range required by the plant. Supplier-supported continuous operating limits and behaviour below the minimum remain separate questions.

The fictional rows below are an original teaching dataset. They are used later for duty weighting; they are not extracted from a supplier graph. The profile deliberately includes a rising specific-power ratio at lower flow to show why a single full-load result cannot replace the table.

Teaching point

Delivery, reference m³/min

Package electrical input, kW

Specific power, kW per m³/min

High

14.4

86.4

6.00

Normal

10.8

64.8

6.00

Low

7.2

45.36

6.30

Minimum shown

4.8

34.56

7.20

For a request between published points, distinguish a supplier-confirmed value from a graph reading or an interpolated estimate. Interpolation may be useful for a declared planning case when the method and curve shape support it, but it is not automatically guaranteed performance. Do not extrapolate beyond the supported range or through a change of control mode.

A maximum-to-minimum flow ratio is only meaningful at compatible conditions. A ratio assembled from maximum flow at one pressure and minimum flow at another is not a demonstrated single-pressure operating range. Likewise, dividing required demand by maximum capacity describes a flow fraction; it does not automatically describe motor speed, electrical load or annual utilisation.

14. Follow the air and electrical boundaries through integrated treatment

An integrated package can include some treatment and exclude other items. Read whether capacity is stated before or after an internal dryer, whether regeneration air is reflected in delivered flow, and which accessory power is included. “With dryer” in the model description does not by itself explain the numerical boundary. Request a simple boundary statement or drawing where the interpretation matters.

For a separately defined system comparison, Q_useful = Q_package − Q_purge − Q_other_losses is a possible steady accounting relationship when all flows share a reference basis and each term is included once. If storage is charging or discharging, or another source feeds the same header, the simple relationship requires additional terms and time alignment. Use it only for the declared case.

Similarly, P_system = P_package + P_external_auxiliaries is meaningful only when the external loads are required, documented and outside the package input. Do not subtract recovered heat from electrical input or label dryer purge as an electrical kW load without a separate model. Keep energy streams and flow streams distinct.

Boundary question

Evidence to request

Reading consequence

Where is capacity measured?

Package terminal location and treatment arrangement

Determines whether an external flow deduction is needed.

Is regeneration consumption included?

Net/gross statement and operating mode

Prevents double deduction or an inflated useful-air figure.

Which fan and drive loads are included?

Package electrical boundary

Prevents adding a package fan twice.

What does the plant supply?

External cooling, ventilation and treatment duties

Creates a separate system-cost and utility review.

At what flow and conditions is treatment rated?

Applicable dryer/filter selection information

Nominal treatment size alone does not establish required service.

15. Read utility and installation requirements as applicability information

A performance sheet can be numerically complete yet insufficient for installation. Check supply voltage, phase and frequency; starting or drive requirements; cooling-water conditions; heat-rejection information; intake and exhaust arrangements; connection sizes; dimensions; mass; and maintenance access. Obtain the relevant installation data where the performance page omits them. These are not optional details if they change whether the quoted package can operate as intended.

A performance declaration for one electrical or cooling variant should not be transferred silently to another. The appropriate supplier may confirm equivalence or provide different data, but the reader should not make that confirmation on the supplier's behalf. Keep “performance rating applies” separate from “installation interfaces resolved.”

For heat recovery, preserve the distinction between available heat and useful heat displaced at the facility. A marketing percentage does not establish annual recoverable value without temperature, demand timing, integration and backup conditions. The reading sheet should record the supplier claim and the missing application evidence; the economic treatment belongs to the lifecycle comparison.

Sound pressure, sound power and pressure dew point also need their own measurement or reporting basis. Do not compare a noise number without its quantity and conditions, or treat a dryer label as a complete particle, oil and moisture guarantee. Cross-reference the applicable supplier documentation instead of filling these fields from a generic expectation.

16. Keep reporting tolerances, uncertainty and acceptance decisions separate

A tolerance printed on a sheet, uncertainty in a field measurement and a contractually accepted performance requirement are different objects. Preserve the source and scope of each. A tolerance may be tied to a test method, capacity band, metric or reporting convention; it is not automatically a design reserve or permission to deliver less useful air than the process requires.

Do not apply the same allowance twice. If the agreed minimum already includes an authorised negative allowance, do not reduce that minimum again when judging the measurement. Equally, do not add flow tolerance and measurement uncertainty as interchangeable favourable adjustments. The applicable acceptance procedure must state how these quantities enter the decision.

At a minimum limit L, y−U ≥ L supports conformity; y+U < L supports nonconformity; an overlapping interval remains indeterminate. At a maximum limit H, y+U ≤ H supports conformity; y−U > H supports nonconformity. Here U is an explicitly supplied uncertainty interval half-width. This is a selected worksheet convention, not a replacement for every contractual or test-code rule.

A near-limit decision must use unrounded calculation values. Missing uncertainty in interval mode is not zero uncertainty. A favourable numerical comparison also cannot close missing configuration evidence, air-quality requirements or site tests. Preserve the scope of the conclusion: a selected criterion may be supported while overall equipment acceptance remains open.

17. Decide comparability before ranking the sheets

Use purpose-specific comparison states rather than a single pass/fail label. Two sheets may be comparable for one rated-point power ratio but not for annual energy, minimum continuous duty, treated delivery or installation suitability. Record the question first. Then identify which conditions must match and which documented differences can be reconciled. [S1–S3; proposed classification]

They organise the evidence; they do not select a supplier or certify an installation.

Reading state

Meaning

Next action

Comparable for stated purpose

Required identity, duty, reference and boundary are established

Perform the stated calculation and retain its limitations.

Comparable after documented adjustment

A valid unit, reference or scope reconciliation is available

Preserve original values, adjustment and adjusted view.

Clarification required

A material definition or operating point is missing

Request the exact item before ranking that criterion.

Not comparable for this purpose

Different duty or method cannot support the proposed comparison

Reframe the comparison or obtain suitable evidence.

Requirement not demonstrated

Available comparable evidence does not establish the required duty

Keep the technical issue separate from price ranking.

Avoid a score that rewards empty fields. A bidder with no part-load data has not demonstrated the same annual-energy evidence as a bidder with a complete table. Nor should an undocumented claim gain an advantage simply because it has more decimal places. Record evidence quality as an explicit review dimension, without inventing statistical confidence percentages.

18. Extract a sheet without losing its qualifications

Use one record for the document, one for the configuration and one for each operating point. Each extracted value should retain the printed quantity, unit, row or note location, source revision and interpretation status. Calculated values belong in separate fields with formula and input references. This structure follows the supplied data-dictionary and acceptance foundations rather than treating a spreadsheet cell as a self-explanatory fact.

Read the complete row and its footnotes together. In a multi-column table, a copied number can move under the wrong heading. In a graph, a drawn line can extend beyond the measured points. Preserve the distinction between printed numeric data, a visual estimate and a supplier-confirmed interpolation. When text extraction is unreliable, inspect the actual page before using a value.

Keep contradictory or unclear entries visible. For example, a heading may use “energy” while the unit is kW. Preserve the source wording, record the unit-based interpretation and seek clarification where the ambiguity affects a decision. Do not silently rewrite the supplier document.

AI-assisted extraction may help locate fields, but it must not invent missing pressure, assume a flow reference, attach a motor rating to the power column or upgrade a published claim into a witnessed result. Require source pointers for material extracted values and review the uncertain fields before they enter downstream comparisons.

19. Worked example one: a rated point and an unloaded-power trap

Fictional case using Section 4. At 7.5 bar gauge, the teaching package delivers 14.4 reference m³/min and draws 86.4 kW electrical. Its nominal motor descriptor is 75 kW. Rated specific power is 86.4/14.4 = 6.00 kW per m³/min; steady specific electrical energy is 86.4/(60 × 14.4) = 0.1000 kWh/m³. The 75 kW descriptor is not used as package input.

Changing only the flow unit gives 14.4/0.028316846592 = 508.53120079 cfm on the same basis. Specific power becomes 100 × 86.4/508.53120079 = 16.99010796 kW per 100 cfm. These are the same performance ratio expressed with different denominator units. Comparing 6.00 directly with 16.99 would be a unit mistake, not an efficiency finding.

Now suppose an explicitly simplified eight-hour operating record is sixty percent loaded and forty percent running unloaded, with unloaded package input of 24.0 kW. Average input is 0.60 × 86.4 + 0.40 × 24.0 = 61.44 kW. Average delivery is 0.60 × 14.4 = 8.64 m³/min. Electrical energy is 491.52 kWh and delivered volume is 4,147.2 m³. The corresponding energy intensity is 0.11851852 kWh/m³.

Multiplying 86.4 kW by sixty percent would give only 51.84 kW and omit 9.60 kW of average unloaded input in this case. Across the eight hours, the omission is 76.80 kWh. The example demonstrates the need for state information; it does not predict an actual compressor's cycling losses, minimum run time or response to changed pressure.

20. Worked example two: weight the variable-speed duty, not the headline

Fictional case using the four published-style teaching points in Section 13. Assume, solely for this comparison, that the package operates exactly at those points for 1,000, 2,000, 2,000 and 1,000 hours respectively. Pressure and flow-reference conditions are compatible, and the electrical boundary is unchanged. Transitions, additional idle periods and external equipment are excluded.

Energy contributions are 86,400, 129,600, 90,720 and 34,560 kWh. Their total is 341,280 kWh over 6,000 hours. Delivered reference-volume contributions are 864,000, 1,296,000, 864,000 and 288,000 m³, totalling 3,312,000 m³. Overall specific electrical energy is 341,280/3,312,000 = 0.10304348 kWh/m³.

The time-weighted mean input is 56.88 kW and the time-weighted mean delivery is 9.20 m³/min. Their ratio is 6.18260870 kW per m³/min. By contrast, a simple arithmetic average of the four row ratios is (6.00 + 6.00 + 6.30 + 7.20)/4 = 6.375. That unweighted average does not represent this duty. The aggregate must retain both time and delivered-volume effects.

The displayed flow range is 14.4/4.8 = 3:1 at the stated conditions. A proposed requirement of 2.4 m³/min lies below the minimum shown and is not covered by this table. A straight line to the origin is not a supplier guarantee. Request supported low-demand behaviour before extending the annual model.

For a separate planning illustration, linear interpolation between 7.2 m³/min at 45.36 kW and 10.8 m³/min at 64.8 kW gives 55.08 kW at 9.0 m³/min. That value must remain labelled an interpolation under an assumed linear segment. It is not one of the stated points and must not be issued as a manufacturer-certified result.

21. Worked example three: the better package ratio may not cover useful delivery

Fictional case. Offer A reports 14.4 reference m³/min at 7.5 bar gauge with 86.4 kW package input. Offer B reports 14.9 m³/min and 88.0 kW at 7.0 bar gauge, but its flow-reference conditions and treatment boundary are missing. Dividing B's two numbers produces an arithmetic ratio, but it does not establish an equivalent-duty comparison with A. B remains clarification-required for the stated comparison.

Now examine a separate, explicitly steady system case for A. Assume documented downstream regeneration consumption is 0.9 reference m³/min and another identified loss is 0.1 reference m³/min. These losses are outside A's declared output and are not already deducted. Useful delivery is 14.4 − 0.9 − 0.1 = 13.4 reference m³/min.

Assume a separately required dryer draws 2.6 kW and an external plant exhaust fan draws 1.0 kW, both outside package input. Wider electrical input is 86.4 + 2.6 + 1.0 = 90.0 kW. The wider ratio is 90.0/13.4 = 6.71641791 kW per m³/min, and specific electrical energy is 0.11194030 kWh/m³. The original package ratio remains 6.00; it has not been “corrected.” A different boundary has been calculated.

If the requirement at this same useful-delivery boundary is 13.8 reference m³/min, the arithmetic shortfall is 0.4 m³/min before any additional site issue is considered. A favourable package-efficiency number does not remove that shortfall. The resulting action is to review a supported system arrangement or revised offer, not to declare the bidder acceptable because its headline ratio is lower.

No gas-state conversion can establish B's performance at A's required discharge pressure. First obtain a compatible operating point and scope statement.

22. Worked example four: tolerance and a near-limit measurement

Fictional case, not a standard tolerance. Suppose a project has explicitly authorised one three-percent negative allowance from a nominal 14.4 m³/min requirement. Its resulting minimum is L = 14.4 × 0.97 = 13.968 m³/min. The allowance has now been applied once. The reading record must preserve the nominal value, authorisation and resulting limit as separate fields.

A compatible test reports y = 13.90 m³/min with an agreed interval half-width U = 0.15 m³/min. Under the optional minimum-limit rule in Section 16, the interval is 13.75–14.05 m³/min. It crosses the minimum, so the selected rule produces an indeterminate flow decision. Reducing 13.968 by another three percent to obtain a more favourable threshold would be a duplicate allowance.

A separate power criterion has a maximum of 90.0 kW. Measured electrical input is 88.0 kW with U = 1.0 kW, giving an upper endpoint of 89.0 kW. That power criterion is supported by the selected rule. It does not turn the indeterminate flow criterion into an overall pass. The measured ratio 88.0/13.90 = 6.33093525 kW per m³/min is retained as a calculation, not used to conceal the individual results.

After an authorised correction and a comparable retest, suppose flow is 14.13 m³/min with the same interval half-width. Its lower endpoint is 13.98 m³/min, which exceeds 13.968. This supports the stated flow criterion under the chosen rule. Retain both runs and the intervention record; do not replace the first result with the second or imply that all untested requirements are complete.

The lesson is to read the acceptance basis before performing acceptance arithmetic. Exact contract terms, test applicability and technical release remain project decisions. The numerical example is a transparent teaching convention, not a legal interpretation or a universal acceptance method.

23. Adapt the reading to technology without transplanting the wrong method

For reciprocating packages, establish whether the quoted figure is displacement or delivered capacity and whether the duty is continuous or subject to a documented operating pattern. For portable diesel equipment, keep engine power, fuel information and delivered air at the selected pressure separate. A diesel engine rating is not interchangeable with an electric package's measured input. The supplied airflow and procurement principles still apply, but their implementation needs the actual supplier documentation.

For centrifugal equipment, a single headline maximum should not replace the relevant operating map and supported control range. Request the duty-specific pressure, flow, inlet and cooling conditions and the supplier's stable-operation constraints. Do not transfer a fixed-speed rotary interpretation into a dynamic compressor's complete selection without checking its own method and configuration.

For boosters, identify both inlet and outlet conditions, the incoming air requirement and the delivered-flow basis. For vacuum duty, retain absolute inlet pressure and the relevant pumping-speed definition; a pressure-air CFM comparison does not establish equivalent vacuum performance. These are applicability questions, not new technology-specific design formulas.

Keep oil-free compression, air-quality evidence and downstream treatment distinct. The equipment description can inform the contamination-control architecture, but it does not establish the condition at every final connection. A performance sheet is one evidence source within a complete selection, not a replacement for the process requirement, installation assessment or sampling plan.

24. Turn common reading failures into specific supplier questions

A useful clarification names the missing field, why it matters and the exact configuration or duty to which the answer must apply. “Please confirm everything is suitable” is weaker than asking for flow and total electrical input at the required pressure, with the declared reference basis and treatment boundary. The following prompts can be used as editable wording, not automatically sent correspondence. [S2; new drafting]

Reading concern

Specific clarification

Keep open until resolved

Model or frequency differs

Provide the sheet for the quoted suffix, voltage, phase and frequency.

Configuration applicability.

Only maximum flow is shown

State delivered flow and package input at the required operating pressure.

Duty and efficiency comparison.

Flow-reference basis is missing

Identify reference pressure, temperature, humidity and measurement terminal.

Capacity reconciliation.

Motor kW is the only power value

Provide total electrical package input and included auxiliary loads.

Energy comparison.

Integrated dryer boundary is unclear

Confirm net delivery, regeneration basis and dryer electrical inclusion.

Useful-air and system-input comparison.

Demand is below the lowest table row

Provide supported minimum continuous duty and lower-demand control behaviour.

Part-load model.

A percentage tolerance is quoted

Identify its source, metric, applicable range and agreed acceptance treatment.

Acceptance criterion.

Site conditions differ

Provide model-specific selection or correction at the stated installation conditions.

Site suitability.

Brochure and sheet disagree

Identify the governing revision and explain the differing values.

Comparison issue status.

Close a question only with the evidence that resolves it. A verbal reassurance or a new price does not establish a missing operating point. Record whether the answer changes the equipment, scope, performance basis or proposed acceptance requirement, and carry that change into the relevant bid and test records.

25. Three editable reading and comparison worksheets

Copy these Word tables for each offer or assessment. Empty entry cells are intentionally editable; they are not zeros, passes or default assumptions. The first worksheet captures the document and duty, the second preserves each extracted point, and the third records conclusions and unresolved clarifications. Keep original supplier files outside the public teaching examples.

Worksheet A — document and requirement

Entry

Source / status

Assessment ID; purpose; prepared by

Supplier; quoted model and suffix

Sheet title; issue date; revision

Electrical and cooling configuration

Required delivery and flow reference

Required pressure and measurement point

Normal / peak / minimum duty hours

Required treatment and external utilities

Original file reference and applicable notes

Worksheet B uses one repeated record per performance point. Do not combine several pressures in an undifferentiated capacity column. Record published, confirmed, measured and estimated values with different status labels.

Worksheet B — operating-point extraction

Supplier entry

Interpretation / evidence

Point ID; exact row or note

Flow value; unit; quantity definition

Reference pressure; temperature; humidity

Operating pressure; gauge/absolute basis

Package input; included auxiliary loads

Control state; supported range

Printed ratio; independently recalculated ratio

Tolerance; method; verification wording

Calculated adjustments and assumptions

Worksheet C — reading disposition

Recorded conclusion

Owner / next evidence

Question the comparison answers

Configuration and duty compatibility

Flow-reference compatibility

Power and treatment boundary compatibility

Missing or conflicting information

Clarification and supplier response reference

Permitted calculation / prohibited inference

Retained limitations and proposed next action

Review date; revision; linked bid or acceptance record

26. Frequently asked questions

Is a 75 kW compressor expected to draw exactly 75 kW? Not necessarily. Establish whether the number is a nominal motor descriptor, shaft power or complete package electrical input. Use the correctly defined input for the duty being compared; do not infer the whole package from its motor nameplate.

Can two CFM values be compared directly? Only after their quantity definitions, reference states, operating pressures and measurement boundaries are reconciled. Pure unit conversion cannot repair unlike reporting conditions.

Does maximum operating pressure carry the same flow and power as the rated row? Do not assume it. Preserve each stated operating point and ask for model-specific evidence where the required duty differs. A maximum capability label is not permission to recombine unrelated numbers.

Why can total package power exceed a nominal motor descriptor? They may represent different quantities and include different loads. Read the electrical-input definition and accessory boundary. Do not infer motor overload or an inaccurate sheet solely from that numerical difference; the relevant motor and package evidence must be reviewed.

Is the lowest specific power always the best selection? It can be a useful result at compatible conditions, but it does not settle capacity, minimum load, air quality, installation, reliability or lifecycle cost. Compare the required service first and the operating profile next.

Can I calculate annual energy from one full-load row? Only for an explicitly stated constant-duty scenario at that row. Variable operation needs supported state or part-load information and defined hours. Label a simplified estimate honestly rather than calling it measured annual performance. [S2; teaching calculations]

Does a variable-speed curve justify extrapolation to zero flow? No. Keep the supported range and low-demand behaviour explicit. An interpolation is an estimate unless the supplier or governing method supports a stronger status. A line drawn on a graph is not a guarantee of every possible operating point.

Does an acceptable package rating prove useful delivery after drying? Not automatically. Follow treatment consumption, pressure losses, external loads and the stated measurement terminals. A separate useful-air comparison must account for each applicable term once.

Can a tolerance be treated as spare capacity? No. A reporting or acceptance provision is not a physical source of additional air. Retain the actual plant requirement and the agreed decision method rather than substituting a favourable percentage.

What should accompany a data-sheet review request? Provide the complete sheet, quoted configuration, required flow and pressure, operating profile, reference basis where known, treatment scope, site conditions and the precise question. Include missing items as open questions. The objective is a defensible reading, not an unsupported approval assembled from incomplete fields.