1. Purpose and Engineering Decision

A measured flow, pressure, power or temperature value is never perfectly exact. More importantly, a calculated result such as specific power or pressure drop inherits uncertainty from every input used to create it.

The worksheet is not a substitute for a calibration certificate, instrument manual or test method. It is the controlled place where those documented inputs are converted to comparable standard uncertainties and combined with sampling and model contributions.

Worksheet mode

Primary output

Single measured quantity

Combined and expanded uncertainty for one measurand

Calculated result

Propagated uncertainty using sensitivity coefficients

Specific power

Uncertainty in kW / delivered reference flow

Pressure difference

Uncertainty in upstream-minus-downstream pressure

Time-series average

Instrument + sampling/data-representativeness uncertainty

Sensitivity review

Ranked contributors to identify the best improvement action

2. Measurement Model Comes First

The worksheet begins with a measurement model: the equation that links the reported result y to the input quantities x1, x2 ... xn.

y = f(x1, x2, ... , xn)

For a direct pressure reading, y may be the corrected pressure itself. For specific power, y = P/Q. For pressure drop, y = P_up - P_down.

3. Standard Uncertainty - Put Different Sources on One Basis

Uncertainty contributions may be documented in different forms: an expanded calibration uncertainty, a plus/minus instrument specification, a resolution increment, a standard deviation from repeated readings or an engineering estimate. They must be converted to standard uncertainty before combination.

Source format

Conversion to standard uncertainty u

Calibration certificate gives expanded U with coverage factor k

u = U / k

Plus/minus a, rectangular assumption

u = a / sqrt(3)

Digital resolution increment q, rounding over half increment

u = q / sqrt(12)

Repeated observations with standard deviation s and n independent observations

u_mean = s / sqrt(n)

Already stated as standard uncertainty

Use directly

Unknown distribution / undocumented basis

Do not guess silently; mark preliminary and state assumption

4. Uncertainty Budget Template - Required Asset

Contributor

Estimate / limit

Distribution / basis

Divisor

Standard u

Sensitivity c

|c|u contribution

Evidence / correlation group

Calibration

Enter certificate U or standard u

Certificate

k or 1

Calculated

1 or model derivative

Calculated

Certificate ID / date

Instrument specification

Enter +/- limit

Rectangular unless documented otherwise

sqrt(3)

Calculated

As model

Calculated

Manual / datasheet

Resolution

Display increment q

Rounding

sqrt(12)

Calculated

As model

Calculated

Instrument

Repeatability

s and n

Observed data

sqrt(n)

Calculated

As model

Calculated

Dataset

Zero / drift

Documented limit

Declared basis

Declared

Calculated

As model

Calculated

Check record

Installation effect

Estimated / tested

Declared basis

Declared

Calculated

As model

Calculated

Installation evidence

Sampling / representativeness

Observed variability

Dataset-derived

Declared method

Calculated

As model

Calculated

Logging window

Model / correction

Correction uncertainty

Declared

Declared

Calculated

As model

Calculated

Method source

5. Sensitivity Coefficients

c_i = partial derivative of y with respect to x_i

u_i(y) = |c_i| x u(x_i)

Sensitivity coefficients convert an input uncertainty into the units of the final result. For a direct measurement y = x, c = 1. For y = P/Q, the sensitivity to power is 1/Q and the sensitivity to flow is -P/Q^2.

6. Combine Independent Contributions by Root-Sum-Square

u_c(y) = sqrt[ Sum( c_i^2 x u_i^2 ) ]

Independent contributions are not normally added arithmetically. Root-sum-square combination reflects the fact that independent errors do not all reach their maximum in the same direction at the same time. A separate worst-case mode may sum limits arithmetically, but it must be labelled as worst-case rather than statistical combined uncertainty.

7. Correlated Inputs

When two inputs share a common calibration, common environmental effect or common reference, their uncertainties may be correlated. Ignoring correlation can either understate or overstate uncertainty.

u_c^2 = Sum(c_i^2 u_i^2) + 2 Sum(c_i c_j rho_ij u_i u_j)

rho is the correlation coefficient between -1 and +1. If correlation is unknown and potentially material, the result should be flagged for review.

8. Expanded Uncertainty and Coverage Factor

U = k x u_c

The worksheet should report both combined standard uncertainty u_c and expanded uncertainty U. The coverage factor k is an explicit user input or method-specific value.

9. Relative Uncertainty

Relative Expanded Uncertainty (%) = U / |y| x 100

Relative uncertainty is useful for comparing measurement quality across different magnitudes.

10. Sampling and Data-Representativeness Uncertainty

A highly accurate meter can still produce a poor plant estimate if the logging window is not representative.

Sampling issue

Worksheet treatment

Short observation window

Estimate variability across repeated comparable windows

Missing intervals

Production mix changes

Segment data or include scenario/representativeness contribution

Start-up / shutdown bias

Flag if sampling window over-represents unusual states

Unsynchronized power and flow

Do not propagate as one specific-power point until aligned

11. Avoid Double Counting

The same physical effect should appear only once in the budget. For example, if a calibration certificate already includes instrument resolution under the exact configuration used, adding a separate resolution term can double count it.

12. Reference Test Case A - Pressure Measurement

A pressure transmitter reports 7.20 bar(g). Calibration expanded uncertainty is +/-0.030 bar with k = 2. A separate documented installation contribution is +/-0.020 bar with rectangular distribution, and display resolution is 0.01 bar.

Contributor

Standard uncertainty (bar)

Calibration

0.0150

Installation

0.0115

Resolution

0.0029

Combined standard u_c

0.0191

Expanded U at k=2

0.0383 bar (0.53%)

Reported screening result: 7.20 bar(g) +/- 0.0383 bar at the stated coverage factor and assumptions.

13. Reference Test Case B - Specific Power

Measured package input is 100.0 kW with standard uncertainty 1.5 kW. Delivered flow is 18.0 m3/min with standard uncertainty 0.45 m3/min. Assume independent inputs.

SP = P / Q

Item

Value

Specific power

5.556 kW/(m3/min)

Power contribution to u(SP)

0.0833

Flow contribution to u(SP)

0.1389

Combined standard u(SP)

0.1620

Expanded U at k=2

0.3239 (5.83% of result)

The flow term dominates this example. Improving power-meter precision would therefore have limited value unless flow uncertainty is also improved.

14. Reference Test Case C - Pressure Drop from Two Sensors

Upstream pressure is 7.10 bar and downstream pressure is 6.85 bar, giving DeltaP = 0.25 bar. Each sensor has standard uncertainty 0.020 bar.

Case

Standard uncertainty of DeltaP

Independent sensors

0.0283 bar

Same-system positive correlation rho=0.8

0.0126 bar

Because the measurement model is upstream minus downstream, positive common-mode correlation can reduce uncertainty in the difference.

15. Reference Test Case D - Time-Series Mean with Sampling Contribution

A 24-hour flow study reports a mean of 12.0 m3/min. Instrument standard uncertainty is 0.24 m3/min. Comparison of repeated representative daily windows gives a sampling/representativeness standard uncertainty of 0.60 m3/min.

Contributor

Standard uncertainty

Instrument

0.24 m3/min

Sampling / representativeness

0.60 m3/min

Combined standard

0.646 m3/min

Expanded U at k=2

1.292 m3/min

This example shows why a long decimal display from a precise instrument does not prove that the annual or plant-wide demand estimate is equally precise.

16. Contributor Ranking

Contribution Share_i (%) = [u_i(y)^2 / u_c(y)^2] x 100

This turns the budget into an action tool: calibrate, improve installation, extend logging, synchronize datasets or leave the measurement system unchanged when the dominant uncertainty lies elsewhere.

17. Decision Margin and Guard Band

When a measured result is compared with a limit, guarantee or acceptance criterion, uncertainty should not be ignored.

The tool must not invent a universal guard band.

18. Input Model

Input group

Field

Validation / note

Result

Measurement model

Required for propagated calculations

Contributor

Source name

Required

Contributor

Estimate / limit

Numeric

Contributor

Basis / distribution

Certificate / rectangular / repeated data / custom

Contributor

Divisor or coverage factor

Positive

Contributor

Standard uncertainty

Calculated or directly entered

Model

Sensitivity coefficient

Required for propagated result

Correlation

Correlation group / rho

Optional but explicit

Coverage

Expanded-uncertainty factor k

Positive

Evidence

Certificate / logger / instrument / dataset reference

Recommended

19. Confidence Model

Budget condition

Suggested confidence

Current calibration evidence + measured repeatability + representative sampling

High

Verified specifications + reasonable sampling evidence

Medium-High

Mixed verified and estimated contributors

Medium

Generic accuracy figures + assumed sampling

Preliminary

Unknown instrument condition or undocumented measurement model

Insufficient for high-confidence decision

20. Validation and Guardrails

Condition

Required behaviour

Negative standard uncertainty

Block calculation

Coverage factor / divisor <= 0

Block calculation

Unknown uncertainty basis

Require explicit assumption; mark preliminary

Potential duplicate contributor

Warn before inclusion

Correlation rho outside -1 to +1

Block calculation

Near-zero result with relative % requested

Prefer absolute uncertainty and warn

Unsynchronized variables in derived KPI

Block propagation or lower confidence

Missing sampling coverage information for time-series claim

Flag result as incomplete

Sensitivity coefficient missing for calculated result

Block combined propagated uncertainty

21. Output Specification

Output

Display rule

Result y

Reported value with units

Combined standard uncertainty u_c

Same units as result

Expanded uncertainty U

Same units + selected k

Relative uncertainty

% where meaningful

Contributor ranking

Variance share %

Correlation record

Groups and rho values used

Evidence trace

Certificate / data source per contributor