1. Purpose and Engineering Decision
A DTH hammer should be compared using the exact equipment identity and the pressure-flow duty supplied by the hammer manufacturer or other accepted technical source. Pressure and airflow must remain paired. A compressor with more nominal CFM is not automatically suitable if that flow is unavailable at the hammer's required working pressure.
Comparison mode | Primary result |
|---|---|
Hammer vs hammer | Pressure-flow evidence and configuration differences |
Hammer vs compressor | Duty coverage at the same pressure |
Multiple operating cases | Minimum / normal / maximum documented duty |
Alternative bit / shank | Change-control warning and revalidation |
Evidence audit | PASS / HOLD / FAIL with reason trace |
2. Required Asset - Hammer Duty Evidence Comparison Worksheet
Field | Hammer A | Hammer B / alternative | Evidence requirement |
|---|---|---|---|
Manufacturer / model | Enter | Enter | Exact identity |
Hammer variant / generation | Enter | Enter | Do not infer from family name |
Bit diameter | Enter | Enter | Actual or intended |
Shank type | Enter | Enter | Exact designation |
Working pressure | Enter | Enter | Documented pressure |
Air consumption | Enter | Enter | Documented flow |
Flow basis | FAD / SCFM / actual / other | Same | Must be defined |
Operating case | Min / normal / max | Same | Source-specific |
Source document | Manual / catalogue / letter | Same | Title + revision/page |
Qualification | Notes | Notes | Site/rig restrictions |
Decision | PASS/HOLD/FAIL | PASS/HOLD/FAIL | Reason required |
3. Keep Pressure and Flow Together
Hammer Duty = (Required Pressure, Required Airflow, Defined Flow Basis, Defined Configuration)
The pair must not be separated. A hammer requirement of 'X m3/min' without its corresponding pressure is incomplete, and a maximum hammer pressure without air-consumption evidence is equally incomplete.
4. Compressor Candidate Must Be Compared at the Same Pressure
Duty Margin_flow = Q_compressor,available_at_required_pressure - Q_hammer,required
Duty Margin_pressure = P_compressor_supported - P_hammer,required
The available compressor flow should come from a model-specific performance table, not the largest flow shown elsewhere in the brochure.
5. Source-Backed Portable Compressor Evidence Examples
The uploaded portable-compressor brochures demonstrate why pressure-flow pairing matters. These are compressor examples only, not hammer requirements.
Candidate example | 7 bar | 10 bar | 12 bar | 14/15 bar | Source note |
|---|---|---|---|---|---|
M81 / M82 | 8.4 m3/min | 6.8 m3/min | 6.1 m3/min | 5.5 m3/min @14 bar | Model-specific technical table |
M31E | 3.15 m3/min | 2.6 m3/min | 2.3 m3/min | 1.9 m3/min @14 bar | Electric portable technical table |
M13 / M13E | 1.20 m3/min | 1.00 m3/min | 0.90 m3/min | 0.75 m3/min @15 bar (M13E) | Small portable technical table |
M50 | 5.0 m3/min | Not shown in supplied M50 table | Not shown | Not shown | Do not invent intermediate points |
This comparison table is intentionally literal. If a pressure point is not published in the supplied source, the worksheet leaves it unavailable instead of interpolating silently.
6. Exact Hammer Identity
A similarly named hammer, a different generation or an undocumented rebuild must not inherit another tool's published duty automatically.
7. Operating Case Register
Case | Use | Rule |
|---|---|---|
Minimum documented duty | Lower supported operating point | Do not call this normal duty unless source says so |
Normal / recommended duty | Primary comparison case | Preferred selection anchor |
Maximum documented duty | Upper supported case | Check compressor envelope and rig limitations |
Special condition | Water, deep hole, flushing, alternative bit | Keep separate until source defines requirement |
8. Flow Basis
Hammer documents and compressor brochures may use different flow conventions. No conversion is made if the source state is unknown.
Flow statement | Treatment |
|---|---|
m3/min FAD | Use as reference flow after basis confirmation |
SCFM / Nm3/h | Normalize to common reference basis |
Actual flow at pressure | Convert only with pressure and temperature state |
Unlabelled CFM | HOLD until source basis is established |
9. Pressure Basis
Working pressure may be shown as bar(g), bar(a), psi(g) or another basis. A pressure unit conversion does not create missing hammer performance data.
10. Compressor Evidence Register
Candidate | Required fields before PASS |
|---|---|
Portable compressor | Model, pressure version, available flow at required pressure, reference basis, ambient/altitude qualification |
Booster-assisted package | Primary compressor duty, booster inlet requirement, booster flow/pressure envelope, interstage losses |
Rental package | Exact supplied model/configuration, hose/manifold arrangement, accessories and site derating basis |
11. Site Qualification Before Final Acceptance
Factor | Why it matters |
|---|---|
Altitude | Lower inlet density can affect compressor/engine capability |
Ambient temperature | Can affect cooling and available performance |
Hose / drill-string loss | Reduces pressure available at hammer |
Leakage | Reduces flow delivered to the tool |
Water / groundwater condition | May change flushing and operating behaviour |
Simultaneous air users | Hammer-only duty may not equal total compressor duty |
Rig limitations | Connections, swivel, drill string and controls can constrain usable duty |
12. Worked Validation Case A - Pressure-Flow Pairing
Synthetic calculator test: Hammer requirement is entered as 6.0 m3/min at 12 bar on a confirmed common reference-flow basis. Candidate X is documented at 8.4 m3/min at 7 bar but 6.1 m3/min at 12 bar.
Flow margin at 12 bar = 6.1 - 6.0 = +0.1 m3/min
The tool compares 6.1 m3/min, not the 8.4 m3/min headline flow. The result may be technically close and should remain subject to site loss, derating and reserve review.
13. Worked Validation Case B - Higher Flow at Wrong Pressure
Synthetic calculator test: Hammer duty is 6.2 m3/min at 12 bar. Candidate Y can provide 7.0 m3/min, but only at 7 bar, with no published 12 bar operating point.
A higher low-pressure CFM value does not prove high-pressure suitability.
14. Worked Validation Case C - Missing Hammer Source Basis
Synthetic calculator test: an enquiry says 'hammer requires 350 CFM' but provides no model, pressure or flow basis.
Required action: obtain hammer identity, applicable manual/catalogue entry, pressure, airflow and basis before compressor acceptance.
15. Worked Validation Case D - Alternative Hammer
Synthetic calculator test: the rig changes from Hammer A to Hammer B after mobilisation. The two hammers share nominal size but have different shank and published duty.
Nominal size similarity is not accepted as evidence that the original compressor duty remains valid.
16. PASS / HOLD / FAIL Logic
Status | Meaning |
|---|---|
PASS - evidence coverage | Required pressure-flow pair is covered by model-specific compressor data and qualifications are accepted |
HOLD - information gap | One or more governing inputs are missing, mismatched or unverified |
FAIL - duty not covered | Documented compressor capability does not meet the required pressure-flow pair |
PASS means the documented air-supply duty is covered. It does not guarantee penetration rate, completed depth, water yield or project duration.
17. Margin Policy
Any reserve allowance must have a stated reason: site uncertainty, leakage, line losses, future demand, simultaneous users or a project-specific acceptance rule.
18. Link to Annular Velocity
A satisfactory hammer-flow comparison does not by itself prove cuttings transport.
19. Input Model
Input group | Field | Validation |
|---|---|---|
Hammer | Manufacturer/model/variant | Required |
Tooling | Bit diameter + shank | Required |
Duty | Pressure | Required |
Duty | Airflow + basis | Required |
Evidence | Document title/revision/page | Required for final PASS |
Compressor | Model / pressure version | Required |
Compressor | Available flow at required pressure | Required |
Site | Altitude / ambient / losses | Explicitly accepted or unresolved |
Decision | PASS/HOLD/FAIL + reason | Required |
20. Validation and Guardrails
Condition | Required behaviour |
|---|---|
Hammer model missing | HOLD |
Pressure missing | HOLD |
Flow basis missing | HOLD |
Candidate flow taken from different pressure | Block comparison |
Unsupported interpolation between compressor points | Block unless supplier method explicitly permits |
Hammer-only duty used as total project demand | Warn and require other users/losses review |
Alternative hammer or bit introduced | Invalidate prior acceptance until rechecked |
PASS used as drilling-performance guarantee | Show limitation warning |